01Sealed System
Freezer Evaporator Coil Replacement Cost
Parts and labour, this repair
$1,400–$3,040
Compressor or sealed-system repair
Compressor, refrigerant leak, evaporator coil: the closed circuit. This is the only work on a freezer where replacing the cabinet is genuinely worth pricing against the repair.
The visit itself is $89, and that comes off the repair the moment you say go. Everything above is the work that follows, on your cabinet, agreed as one figure first.
What is included
- The rear panel out, the coil thawed and inspected, and the decision made on evidence
- Recovery of the charge, the coil and drier changed together, and the circuit dried out
- A weighed charge and a logged recovery to set point before the panel goes back on
- The drain trough behind the coil cleared while it is open, since it rarely is otherwise
What changes the price
- Whether corrosion has reached tubing beyond the coil, which widens the job considerably
- Whether a drawer stack and its runners have to come out before the panel can
- How much of the cabinet has to be drawn out, which on a tall built-in is the slow part
Replaced, or cleared and left alone
Most iced coils are not replaced. Frost on the fins is a defrost story, and a coil that comes out of a bad month of icing usually goes straight back in unharmed once the heater, the sensor or the control behind it has been sorted out.
A coil is changed when it has stopped holding refrigerant: a weep at a bend, corrosion under the frost line, damage from something driven into the fins. That is a hole in the sealed circuit, and no amount of thawing will close it.
What the visit looks like
The rear panel comes off and the coil is brought back up to temperature so it can be inspected properly. If it is leaking, the charge is recovered, coil and drier come out together, the joints are remade and the circuit is dried before anything new goes in. The last stretch of the appointment is spent watching the box come down and stay down.
Where this goes next
One common way this surfaces is asa freezer that never came back after an outage, though the outage is seldom the real cause.
Where the pump has gone with it, the larger job isa compressor replacement, inside this same band.
Replacing the coil or simply clearing it is a reading rather than an opinion, and it comes fromthe diagnosis visit.
Asked before the visit
Why is a coil priced with the compressor and not with the fan?
Because the coil belongs to the closed circuit. Reaching it means recovering the refrigerant, cutting into sealed tubing and rebuilding the charge afterwards, which is the same order of work as a pump change. The fan sitting in front of it is a different band entirely.
Can an iced-up coil be replaced instead of thawed every month?
Ice on a coil is usually a defrost fault rather than a dead coil, and swapping the coil would leave the real cause running. A coil is changed when it leaks or corrodes through. Sub-Zero Repair Experts Los Angeles checks that order before quoting — (310) 496-3358.
Afterwards
What people said once the kitchen was back together
Built-in Sub-Zero calls on both sides of the pass.
Owners on this route5.0/ 51,305 reviews
Cubes came out cloudy and welded into one lump. The inlet valve was barely opening and the filter had not been touched since our remodel. Both replaced, line flushed, and the ice is clean.
Desmond C.Silver Lake
The door stopped sealing and the cabinet sweated every afternoon. The vacuum seal had split along the hinge side and the door sat low. New gasket, hinge shimmed.
Adela S.Sherman Oaks
Cubes were forming half size and the cycles dragged on far too long. A partly closed saddle valve under the sink was starving it of water. He replaced that, checked flow, and bins have been full.
Xiomara J.Sherman Oaks
Evaporator coil, quoted before it is started